Skip to content
R-22 compressor replacement in West Athens, Los Angeles: new scroll compressor brazed into the condensing unit

Case Study 001 · Residential · Los Angeles CountyR-22 compressor replacement
in West Athens, Los Angeles.

This R-22 compressor replacement started with an outdoor unit that buzzed and vents that blew warm air. Here is the whole job, photo by photo: what failed, the two options we put in writing, everything we replaced and how the system came back to life.

WO-000003AUG 29 → SEP 17, 202617 PHOTOS FROM THE JOB
  • Same dayDiagnosis on site
  • 2 optionsQuoted in writing
  • 6 partsReplaced in one visit
  • RS-44bR-22 retrofit
// The job

R-22 compressor replacement in Los Angeles, start to finish.

A homeowner in West Athens called on a hot August afternoon: the outdoor unit was buzzing and the house wasn’t cooling. The compressor on their R-22 system had failed. Instead of pushing a new system, we priced both paths in writing, a repair with an RS-44b retrofit or a full replacement, and let the customer choose.

They chose the repair. The R-22 compressor replacement cost less than a third of a new system, and the AC was cooling again the same afternoon we did the work.

JOB FILE · WO-000003CLOSED
  • Location: West Athens, Los Angeles County
  • Equipment: R-22 split system, scroll compressor
  • Complaint: Outdoor unit buzzing, no cool air
  • Diagnosis: Compressor failed, condemned
  • Options: Repair or full replacement, both in writing
  • Decision: Customer chose the repair
  • Refrigerant: R-22 recovered, retrofit to RS-44b
  • Status: Cooling again, same day
// Timeline

From the first call to cold air.

Every step logged in our dispatch system, with dates, quotes and approvals on file.

  1. 01 · AUG 29 · THE CALLBuzzing, no cool air

    The outdoor unit was humming, the compressor wouldn’t start and warm air was coming out of every vent. We were on site that afternoon.

  2. 02 · AUG 29 · DIAGNOSISCompressor condemned

    Electrical tests on site confirmed the compressor had failed. On an R-22 system, that leaves two honest options, and the customer deserved to see both.

  3. 03 · SEP 8 · TWO QUOTESRepair or replace, in writing

    Option one: repair the existing unit and retrofit it to RS-44b. Option two: a complete new system, with the city permit and HERS verification included. The repair came in at less than a third of the replacement.

  4. 04 · SEP 9 · APPROVEDThe customer chose the repair

    Approved by email on September 9. A week later the customer also approved, by text, replacing the old fused disconnect box.

  5. 05 · SEP 17 · REPAIR DAYCooling again by the afternoon

    The R-22 compressor replacement itself: new compressor, fan motor, blade, capacitor, contactor and disconnect, then a full evacuation, a new charge and a start-up test.

// Photo by photo

What came out, what went in.

Every photo below is from this R-22 compressor replacement, in the order the work was done. New parts are marked with the install date.

01 · AUG 29Diagnosis
Failed R-22 scroll compressor inside a residential condensing unit in West Athens, Los Angeles
AUG 29 · R-22 COMPRESSOR, CONDEMNED
Electrical diagnosis of an AC condensing unit with a clamp meter in West Athens, Los Angeles
AUG 29 · ELECTRICAL DIAGNOSIS
02 · SEP 17What came out
Original capacitor and contactor in the control panel of an R-22 condensing unit in Los Angeles
OLD CONTROL PANEL
Old fused AC disconnect box opened before replacement in West Athens, Los Angeles
OLD FUSED DISCONNECT
Old condenser fan motor and fan blade removed from an AC unit in Los Angeles
OLD FAN MOTOR AND BLADE, REMOVED
Failed compressor still in place inside an R-22 condensing unit in West Athens
OLD COMPRESSOR, IN PLACE
Condensing unit with the failed compressor removed in West Athens, Los Angeles
OLD COMPRESSOR, REMOVED
Old AC contactor removed and set on top of the condensing unit in Los Angeles
OLD CONTACTOR, REMOVED
03 · SEP 17What went in
New fused AC disconnect box installed next to the condensing unit in West Athens, Los Angeles
NEW FUSED DISCONNECT
New scroll compressor brazed into an R-22 condensing unit in West Athens, Los Angeles
NEW COMPRESSOR, BRAZED IN
New AC compressor marked with the install date 9.17.26 in West Athens, Los Angeles
NEW COMPRESSOR · DATED 9.17.26
New condenser fan motor and fan blade installed and dated on an AC unit in Los Angeles
NEW FAN MOTOR AND BLADE
Old 2017 dual run capacitor next to the new 45/5 MFD capacitor, Los Angeles AC repair
OLD (2017) VS NEW CAPACITOR
New dual run capacitor and contactor installed and dated in an AC control panel in Los Angeles
NEW CAPACITOR AND CONTACTOR
04 · SEP 17Charge and start-up
AC system being charged with refrigerant on a scale with manifold gauges in West Athens, Los Angeles
CHARGE AND START-UP
Supply air reading of 48.9 degrees at a register after the AC compressor replacement in West Athens, Los Angeles
SUPPLY AIR · 48.9°F
Thermostat dropping to 79 degrees after the AC compressor replacement in West Athens, Los Angeles
THERMOSTAT · DOWN FROM 80°F
// Parts and labor

Everything we replaced.

When a compressor fails, the parts around it usually took a beating too. That is why every R-22 compressor replacement we do includes a close look at the fan motor, capacitor, contactor and disconnect, and we replace what is worn in the same visit, so the new compressor starts its life on a healthy system.

Want this kind of failure caught early? See our HVAC maintenance plan, or our residential HVAC service.

WORK COMPLETED · SEP 17DONE
  • New scroll compressor, brazed in and dated
  • New condenser fan motor and fan blade
  • New 45/5 MFD dual run capacitor
  • New contactor
  • New fused disconnect box with new fuses
  • R-22 recovered and disposed of properly
  • Retrofit to RS-44b with a full evacuation
  • Charge and start-up test
// AC not cooling?

Buzzing outdoor unit? Call before it gets worse.

Whether it turns out to be an R-22 compressor replacement or a simple capacitor, we diagnose AC problems across Los Angeles County and the rest of Southern and Central California, and we put every repair option in writing before we touch anything. See our AC repair and 24/7 emergency HVAC service. All work is done under California CSLB C-20 license #1155621, and you can verify our license on the CSLB website.

// Compressor replacement · FAQ

Can you do an R-22 compressor replacement without replacing the whole system?

Yes, when the rest of the system is in good shape. We recover the R-22, replace the compressor and the parts that failed with it, and retrofit the system to an approved replacement refrigerant like RS-44b. In this job, the R-22 compressor replacement cost less than a third of a full replacement.

Why not just recharge the system with R-22?

R-22 has not been produced in the U.S. since 2020, so what is left is scarce and expensive. A retrofit to RS-44b lets an older system keep running without depending on R-22. That is why every R-22 compressor replacement we do includes the retrofit.

Is an R-22 compressor replacement worth it on an older AC?

It depends on the condition of the coils, the line set and the rest of the unit. That is why we quote both options in writing and let you decide with real numbers in front of you.

My outdoor unit is buzzing but the AC is not cooling. What should I do?

Turn the system off at the thermostat and call us. A buzzing unit that is not cooling can be a bad capacitor, a contactor or a failed compressor, and running it like that can turn a small repair into a big one. See our AC repair service.

Do you work in my area?

We serve homes and businesses across Los Angeles County, the San Fernando Valley, Orange County, Ventura County, the Inland Empire, the Central Coast, the Central Valley and Kern County. Check your ZIP code.

// Case Studies · Real jobs, photos and readings 844-FIX-UR-AC
Scroll to Top